GANZ Ansaldo DXM 80 000/145 Power Transformer – 80 MVA – 132/10.5 kV – 50 Hz – 1998

Product Details

Output
80 MVA
Year
1998
Condition
Used
Location
Europe
Per Unit PricePrice on request
Direct listing
AI Mode
Equipment data

Technical specifications

Model Number
DXM 80 000/145
Output Power
80 MVA
Manufacturer Name
GANZ Ansaldo
Year of Manufacturing
1998
Available on request

Supporting Documents

At a glance

Short Description

Used GANZ Ansaldo DXM 80 000/145 three-phase, oil-immersed, two-winding power transformer, rated 80 MVA at 50 Hz with a 132/10.5 kV voltage ratio. Manufactured and commissioned in 1998, it is a generator step-up unit with OFAF cooling, currently installed. One unit is available, in Europe.

Asset overview

Description

This is a used GANZ Ansaldo DXM 80 000/145 three-phase, oil-immersed, two-winding power transformer, rated 80 MVA at 50 Hz with a 132 / 10.5 kV voltage ratio. It was manufactured and commissioned in 1998 and is offered used. One unit is available, currently installed, in Europe.

The transformer is arranged as a generator step-up (GSU) unit, vector group YNd11, with a short-circuit impedance of 12.5%. Cooling is OFAF (forced oil, forced air). Rated current is 350 / 4,400 A. Oil and winding temperature rises are 60 °C and 65 °C. The tank and conservator are rated for 1.0 bar pressure and full vacuum. Total weight with oil is 94.5 t, with a transport weight of 83 t with oil or 72 t with nitrogen.

The scope of supply is the complete main transformer (active part and tank) with HV, LV and neutral bushings, conservator with breather, OFAF cooling equipment (coolers, oil pumps and fans), a tap changer, insulating oil, protection devices (Buchholz, PRD and temperature indicators), a marshalling / control cabinet, and original drawings and test documentation. The technical information pack and photos are attached.

Specifications

ParameterDetails
Manufacturer / ModelGANZ Ansaldo DXM 80 000/145
TypeThree-phase, oil-immersed, two-winding power transformer
Rated Power80 MVA
Rated Voltage132 / 10.5 kV
Rated Current350 / 4,400 A
Frequency50 Hz
Vector GroupYNd11
Short-circuit Impedance12.5%
CoolingOFAF (forced oil, forced air)
Oil / Winding Temperature Rise60 °C / 65 °C
Tank and ConservatorRated for 1.0 bar pressure and full vacuum
Typical ApplicationGenerator step-up (GSU)
Year of Manufacture1998 (commissioned 1998)
Total Weight with Oil94.5 t
Transport Weight with Oil83 t
Transport Weight with N272 t
ConditionUsed, currently installed
Availability1 unit available
Location / TermsEurope

Scope of Supply

SystemEquipment
Main Transformer1 × GANZ Ansaldo DXM 80 000/145 active part and tank
BushingsHV, LV and neutral bushings
ConservatorConservator with breather
CoolingOFAF cooling equipment (coolers, oil pumps, fans)
Tap ChangerTap changer (type and range not stated in the pack)
Insulating OilInsulating oil included
ProtectionBuchholz, PRD and temperature indicators
ControlsMarshalling / control cabinet
DocumentationOriginal drawings and test documentation

 

If you require any further information on this listing please contact info@reflowx.com

Before you buy

General Terms

  • ReflowX and the seller retain the right to evaluate and approve offers.
  • Buyers should verify quantities and conditions upon delivery.
  • After successful engagement, both buyer and seller manage communication for payment terms and delivery schedule.
  • All parties agree to adhere to ReflowX Terms and Conditions in transactions.
  • Buyers can request value-added services such as pre-purchase inspections, Expediting & Delivery Services through ReflowX. Contact us!
Full lifecycle support

From technical review to installation.

Submit an RFQ
Similar equipment

You may also like

View all equipment →
AREVA / GE Vernova 112/168 MVA Power Transformer – 230/11 kV – 50 Hz – 2005 Technical dataAvailable
Power & Step-Up Transformers

AREVA / GE Vernova 112/168 MVA Power Transformer – 230/11 kV – 50 Hz – 2005

JSHP 80 MVA Power Transformer – 161/11.5/11.5 kV – 50 Hz – 2016 Technical dataAvailable
Power & Step-Up Transformers

JSHP 80 MVA Power Transformer – 161/11.5/11.5 kV – 50 Hz – 2016

Alstom Power Transformer – 90/11 kV YNd11 – 50 Hz – 1999 Technical dataAvailable
Power & Step-Up Transformers

Alstom Power Transformer – 90/11 kV YNd11 – 50 Hz – 1999