HomeProduct

Description

This listing covers two multi-shaft combined cycle packages, each made up of two GE MS9001E gas turbines (about 102 MW each) and one Toshiba tandem-compound steam turbine (about 109 MW), roughly 310 MW per package at 50 Hz. The equipment was built in 1990-1991 and runs on dual fuel. It is retired and decommissioned and used, maintained equipment is available as the full set of 4 gas turbines and 2 steam turbines.

The gas turbines have between about 121,500 and 132,100 operating hours and the steam turbine about 147,931 hours. Final gas turbine major overhauls were completed in 2012-2013, including generator re-insulation. Each package covers a gas turbine island with GE 9H2 hydrogen-cooled generator and a steam turbine island with Toshiba generator, condenser, feed water system and DCS. The technical information pack and photos are attached.

Specifications

ParameterDetails
Configuration2 packages, each 2 gas turbines + 1 steam turbine (4 GT + 2 ST in total)
Gas TurbinesGE MS9001E (PG9161E, upgraded to PG9171E), about 102 MW each
Steam TurbineToshiba tandem compound TCDF-23", about 109 MW each
Package OutputApprox. 310 MW per package
Frequency50 Hz
FuelDual fuel
Year of Manufacture1990-1991 (commissioned 1990-1992)
Operating HoursGT approx. 121,500-132,100 h; ST approx. 147,931 h
StartsGT approx. 333-1,020
GeneratorsGE 9H2 hydrogen-cooled, 128.6 MVA; Toshiba TAKL, 145 MVA
Condition / AvailabilityUsed, maintained; retired / decommissioned

Scope of Supply

SystemEquipment
Gas Turbine Island (per package)GE MS9001E gas turbine cores with GE 9H2 generators, air inlet filter house, compressor wash skid, fuel gas scrubber, dual-fuel forwarding and water injection skids
GT Auxiliaries & ControlsFin-fan cooling module, CO2 fire protection, GE Speedtronic Mark VI control system and EX2100 static exciter
ElectricalMain and auxiliary transformers, auxiliary breakers and isolated phase bus ducts
Steam Turbine Island (per package)Toshiba TCDF-23" steam turbine core with TAKL generator, main steam control valves, surface condenser and vacuum unit
Water & Oil SystemsBoiler feed water pumps, closed cooling water pumps, deaerator tank, lube oil / hydraulic tanks with jacking oil system and purifier
Plant ControlsDistributed Control System (DCS), EX2100 exciter and station battery systems

 

If you require any further information on this listing please contact info@reflowx.com

Technical Details

Year of Manufacturing1990-1991
Model NumberMS9001E / TCDF-23"
Fuel typeDual Fuel
Usage Hours121,500-132,100 hrs (GT)
Manufacturer NameGeneral Electric / Toshiba
VoltageGE 9H2 (128.6 MVA, 11.5 kV) & Toshiba TAKL (145 MVA, 13.8 kV)
Temperature Range11,317 kJ/kWh (LHV)
Ready for InspectionYes
Owner typeDirect Owner
Availability StatusAvailable
Frequency50 Hz
Output Power310 MW per package
Turbine CycleCombined Cycle

Supporting Documents

General Terms

  • ReflowX and the seller retain the right to evaluate and approve offers.
  • Buyers should verify quantities and conditions upon delivery.
  • After successful engagement, both buyer and seller manage communication for payment terms and delivery schedule.
  • All parties agree to adhere to ReflowX Terms and Conditions in transactions.
  • Buyers can request value-added services such as pre-purchase inspections, Expediting & Delivery Services through ReflowX. Contact us!
Reflowx icon

ReflowX - A Trusted Marketplace for Surplus Energy Sector Equipment

Shape a sustainable and circular future while reducing costs and carbon emissions with us.

  • ✅ Free Listings, No Hidden Fees
  • ✅ Low-Cost Procurement
  • ✅ Cost Recovery Solutions
  • ✅ Tailored Sales Support
App StoreGoogle Play
Mobile App