- Home/
- Gas Turbine/
- Aeroderivative/
- Solar Taurus 60 Gas Turbine Generator Package – 5.5 MW – 50 Hz – 2003
Description
This Solar Taurus 60 gas turbine generator package is rated at 5.5 MW at 50 Hz and runs on dual fuel, pipeline natural gas with automatic transfer to distillate diesel. It was manufactured in 2003 and commissioned in 2004, and the gas generator core was replaced in 2022. The package has 144,850 operating hours, of which the current core has 5,960 fired hours. It is fully operational and one package is available.
It has been maintained under a Solar Turbines maintenance service agreement, with annual Level A and B checks. The package has an epicyclic reduction gearbox of 8,300 HP and a Leroy-Somer generator. The technical information pack and photos are attached.
Specifications
| Parameter | Details |
|---|---|
| Manufacturer / Model | Solar Turbines Taurus 60 |
| Configuration | Gas turbine generator package, baseload |
| Rated Output | 5.5 MW |
| Frequency | 50 Hz |
| Fuel | Dual fuel: pipeline natural gas and distillate diesel |
| Year of Manufacture | 2003 (commissioned 2004; core replaced 2022) |
| Operating Hours | 144,850 h (package); 5,960 h (current core) |
| Gearbox | Epicyclic reduction gearbox, 8,300 HP, 14,944 to 1,500 rpm |
| Generator | Leroy-Somer |
| Condition / Availability | Used, maintained; fully operational; 1 package available |
Scope of Supply
| System | Equipment |
|---|---|
| Gas Turbine | Taurus 60 gas turbine with variable guide vanes and axial power turbine (core replaced 2022) |
| Gearbox & Generator | Epicyclic reduction gearbox and Leroy-Somer generator |
| Fuel System | Dual-fuel system with automatic gas-to-diesel transfer |
| Lubrication | Forced-feed lube oil system with duplex filtration and fin-fan cooling |
| Controls & Safety | Control console, overspeed backup protection, gas detection and fuel safety switches, battery banks |
If you require any further information on this listing please contact info@reflowx.com
Technical Details
| Year of Manufacturing | 2003 |
|---|---|
| Model Number | Taurus 60 |
| Fuel type | Dual Fuel (Natural Gas / Distillate) |
| Usage Hours | 144,850 hrs (package) |
| Manufacturer Name | Solar Turbines |
| Ready for Inspection | Yes |
| Owner type | Direct Owner |
| Availability Status | Available |
| Frequency | 50 Hz |
| Output Power | 5.5 MW |
Supporting Documents
General Terms
- ReflowX and the seller retain the right to evaluate and approve offers.
- Buyers should verify quantities and conditions upon delivery.
- After successful engagement, both buyer and seller manage communication for payment terms and delivery schedule.
- All parties agree to adhere to ReflowX Terms and Conditions in transactions.
- Buyers can request value-added services such as pre-purchase inspections, Expediting & Delivery Services through ReflowX. Contact us!