- Home/
- Gas Turbine/
- Heavy Duty Frame/
- 2 x GE Frame 9E (PG9171E) Gas Turbine Power Plants – 122 MW each – 50 Hz – 1999
Description
This package comprises two GE Frame 9E (PG9171E) single-shaft, open-cycle gas turbine power plants running at 3,000 rpm and 50 Hz. Unit 1 is rated 123.4 MW and unit 2 122.6 MW at ISO on natural gas, about 245 MW combined, and about 120.7 MW per unit on distillate. They were manufactured in 1999 and commissioned in 2000, and run on natural gas with diesel as backup fuel.
Unit 1 has 51,340 operating hours and unit 2 has 49,943 hours, each with 2,437 starts. Both are installed and in active peaking service. Unit 1 had its last major inspection in 2021 with a liner replacement, and unit 2 in 2017 with combustion inspections in 2020 and 2023. Plant availability was 93 to 98 percent over 2022 to 2025.
Each unit is a complete plant with its turbine, 15 kV air-cooled generator, Mark V controls, auxiliaries and exhaust, plus shared fuel and injection-water systems and an emergency diesel generator. The technical information pack is attached.
Specifications
| Parameter | Details |
|---|---|
| Manufacturer / Model | GE / Alstom (European Gas Turbines) Frame 9E, PG9171E |
| Configuration | 2 x single-shaft open-cycle gas turbine plants |
| Rated Output | Unit 1: 123.4 MW; unit 2: 122.6 MW (ISO, natural gas); about 245 MW combined |
| Frequency | 50 Hz (3,000 rpm) |
| Fuel | Natural gas (main), diesel (backup) |
| Combustion | DLN1 dry low NOx on gas; water injection on liquid fuel; 14 combustion chambers per unit |
| Year of Manufacture | 1999 (commissioned 2000) |
| Operating Hours | Unit 1: 51,340 h; unit 2: 49,943 h |
| Starts | 2,437 per unit |
| Generators | 2 x Alstom air-cooled, 15 kV, about 165 MVA each |
| Controls | Speedtronic Mark V |
| Condition / Availability | Used, installed and operational (peaking duty); 2 units available |
Scope of Supply
| System | Equipment |
|---|---|
| Gas Turbines | 2 x GE Frame 9E gas turbines on base, with acoustic enclosures |
| Generators | 2 x air-cooled generators with generator circuit breakers |
| Air Intake | 2 x intake systems with filter house, duct, silencer and support structure |
| Exhaust | 2 x exhaust ducts, silencers and stacks |
| Controls | 2 x Mark V control systems with turbine control compartments |
| Auxiliary Systems | Lube oil with oil mist eliminators; closed-loop cooling water with fin-fan coolers; liquid fuel pumping and filtration; water injection skids; CO2 fire protection |
| Transformers & Power | 2 x main step-up transformers, 2 x 4 MVA auxiliary transformers, 2 x MCC / auxiliary power distribution |
| Fuel Systems | Natural gas receiving station with filtration and metering; liquid fuel transfer skid; injection water transfer skid |
| Emergency Power | 1 x emergency diesel generator |
| Other | Walkways, platforms, interconnecting piping and cabling; as-built drawing sets (mechanical, electrical, I&C, civil) |
If you require any further information on this listing please contact info@reflowx.com
Technical Details
| Fuel type | Natural Gas / Diesel |
|---|---|
| Usage Hours | Approx. 50,000 hrs per unit |
| Model Number | Frame 9E (PG9171E) |
| Output Power | 122 MW per unit |
| Turbine Cycle | Simple Cycle |
| Manufacturer Name | General Electric |
| Year of Manufacturing | 1999 |
Supporting Documents
General Terms
- ReflowX and the seller retain the right to evaluate and approve offers.
- Buyers should verify quantities and conditions upon delivery.
- After successful engagement, both buyer and seller manage communication for payment terms and delivery schedule.
- All parties agree to adhere to ReflowX Terms and Conditions in transactions.
- Buyers can request value-added services such as pre-purchase inspections, Expediting & Delivery Services through ReflowX. Contact us!