2045 kVA Diesel Generator | Cummins QSK60-G4 | 400V | Stamford LSA52.3 L9 | D510C AVR

Diesel Generator Set 2045 kVA (400V, 3PH, 50Hz) — CUMMINS QSK60-G4

ReflowX SKU: REF-4753

Product Details

  • Quantity
    2
  • Availability (Lead Time)
    0-2 Weeks
  • Product Location
    United Arab Emirates
  • Condition
    New
  • OEM
    Perkins
  • Equipment code
    gen-d

Short Description

AQT-CU2250 GENERATING SET CU2250KVA

Description

GENERAL DESCRIPTION

The CU-2250 diesel generator set delivers dependable, high-capacity power for continuous and emergency operation in industrial applications. Powered by a Cummins QSK60-G4 turbocharged aftercooled engine and equipped with a high-performance brushless AC alternator, this unit guarantees robust, stable, and efficient operation, designed in accordance with global generator standards.

POWER RATINGS

Prime Rating: 2045 kVA / 1636 kW at 50 Hz, 1500 rpm

Standby Rating: 2250 kVA / 1800 kW at 50 Hz, 1500 rpm

Prime rating allows unlimited hours of usage with an average load factor of 80% over each 24-hour period. A 10% overload is available for 1 hour in every 12 hours of operation.
Standby rating is limited to 500 hours annual usage, with an average load factor of 80% of the standby rating. Up to 300 hours can be run continuously. No overload is permitted on standby.

ENGINE SPECIFICATIONS

Engine Make: Cummins

Engine Model: QSK60-G4

Type: 4-Cycle, 16-Cylinder, Turbocharged, Aftercooled Diesel Engine

Aspiration: Turbocharged & Aftercooled

Cooling Method: Water-Cooled with 50°C Radiator and Protective Fan Shroud

Bore x Stroke: 159 mm x 190 mm

Displacement: 60.2 Litres

Governing Type: Electronic Governor

Compression Ratio: 13.5:1 (typical for this model range)

Fuel System: Cummins HPI Direct Injection

Fuel Filter: Dual Spin-On Fuel Filters with Water Separator

Lube Oil Filter: Spin-On Full Flow Filter

Lubrication Oil Capacity: 280 Litres

Battery Charging Alternator: 55 AMP, 24 Volt

Starting Voltage: 24 Volt

Starting Motor: Heavy-duty 24V electric starter

ALTERNATOR SPECIFICATIONS

Alternator Make: AQT I Leroy Somer / Stamford

Alternator Model: AQT I LSA52.3 L9 (or equivalent)

Type: Brushless AC Alternator

Output Rating: 2045 kVA Prime / 2250 kVA Standby

Number of Poles: 4

Winding Pitch: 2/3

Insulation Class: Class H

Temperature Rise: 125°C at 40°C ambient

Ingress Protection Rating: IP23

Excitation System: AREP + PMI

Automatic Voltage Regulator (AVR) Model: D 510C

Voltage Regulation: ±0.5%

Harmonic Coefficient (THF): < 3.5%

Telephone Influence Factor (TIF): < 50

Cooling Air Flow: 2.5 m³/sec

COMPLIANCE & STANDARDS

Manufactured and tested in compliance with:
ISO 3046, ISO 8528, BS 5000, DIN 6271, DIN EN, IEC 60034, IEC 60947-2, BS 5514, NEMA MG1

FEATURES

Heavy-duty Cummins QSK60-G4 16-cylinder turbocharged aftercooled diesel engine

Robust brushless AC alternator with AREP excitation for superior transient response

Low harmonic distortion (THF < 3.5%) for sensitive electrical loads

D 510C AVR ensures precise voltage control under varying load conditions

Dual spin-on fuel filters with water separator for maximum engine protection

Spin-on full flow oil filters for ease of service

High capacity 280-litre oil system for extended operating intervals

50°C radiator with protective fan shroud for demanding environments

Fully compliant with major global generator standards

For further specifications or to inquire about this equipment and ReflowX's logistics services, Please contact ReflowX at info@reflowx.com 

Technical Details

Model Number
CUMMINS QSK60-G4
Model Number
CUMMINS QSK60-G4
Height
2550 mm
Width
2300 mm
Length
5850 mm
Weight
Approx. 9000 kg
Usage Hours
00
Voltage
400V
ISO 15926 Pt 4
2353
PCA RDS Code
RDS873359
CFIHOS ID
CFIHOS-30000804
Output Power
1840 kVA / 1472 kW
Speed
1500 RPM
Direction of Rotation
Clockwise
IFC Class
IfcElectricGenerator
Explosion Protection Temperature Class
T3 or T4
Explosion Protection Zone
Zone 2
Lower Limit Operating Temperature
–10°C (standard), –25°C with optional cold weather kit
Operation Continuous Intermittent
Continuous (Prime) / Intermittent (Standby)
Upper Limit Operating Temperature
+50°C (derating applies above 40°C)

General Terms

  • ReflowX and the seller retain the right to evaluate and approve offers.
  • Buyers should verify quantities and conditions upon delivery.
  • After successful engagement, both buyer and seller manage communication for payment terms and delivery schedule.
  • All parties agree to adhere to ReflowX Terms and Conditions in transactions.
  • Buyers can request value-added services such as pre-purchase inspections, Expediting & Delivery Services through ReflowX. Contact us!

Similar Products in Diesel Generator


What Our Customers Say

Reflowx icon

ReflowX - A Trusted Marketplace for Surplus Energy Sector Equipment

Shape a sustainable and circular future while reducing costs and carbon emissions with us.

  • ✅ Free Listings
  • ✅ Low-Cost Procurement
  • ✅ Cost Recovery Solutions
  • ✅ Tailored Sales Support
Mobile App

Tell Us Your Requirement Surplus Equipment | New Equipment | Sustainable Procurement

All Categories×
Heavy Equipment
Heavy Equipment
Heavy Equipment ×