- Home/
- Power Generation/
- Gas Turbine/
- GE LM2500+ SAC RC Model Gas Turbine Genset – Overhauled Package with Brush Generator
Description
GE LM2500+ SAC RC Model Gas Turbine Genset
Offered for sale is a GE LM2500+ SAC RC Model Gas Turbine Generator Set, delivered with complete overhaul and refurbishment services. The scope includes a major overhaul of the gas turbine, refurbishment of the Brush generator and GTG package, and complete dismantling, crating, and loading onto trucks for transport. The estimated schedule spans approximately 30 weeks total, ensuring optimal operational reliability.
Buyers will benefit from a 12-month warranty from operation or 18 months from delivery, covering all major overhauled components. Ideal for industrial or utility power generation, this package ensures dependable performance and complete refurbishment compliance. Full commercial and technical details available upon serious inquiry.
Specifications
– Turbine Type: GE LM2500+ SAC RC Model
– Package: Gas Turbine Generator Set with Brush Generator
– Service Scope:
Major Overhaul Duration: 20 weeks
Crating and Loading Duration: 4 weeks
Generator Refurbishment Duration: 6 weeks
– Warranty:
12 months from operation or
18 months from delivery
– Included Services:
Gas turbine inspection and overhaul
Brush generator & GTG package refurbishment
Dismantling, re-crating, and truck loading
– Delivery: Upon completion of overhaul schedule
For further specifications or to inquire about this equipment and ReflowX's logistics services, Please contact ReflowX at info@reflowx.com
Technical Details
| Model Number | GE LM2500+ SAC RC Model |
|---|---|
| Manufacturer Name | GE |
| Temperature Range | −50°C to +50°C |
| Pressure Rating | 17 bar |
| Voltage | 11 kV to 13.8 kV |
| ISO 15926 Pt 4 | 7686 |
| PCA RDS Code | RDS820799 |
| CFIHOS ID | CFIHOS-30000534 |
| Fuel type | Natural Gas |
| Output Power | 32 – 34 MW |
| Speed | 3,000 RPM |
| Direction of Rotation | Clockwise |
| Normal Operating Temperature | 15°C to 38°C |
| Lower Limit Operating Temperature | −50°C |
| Operation Continuous Intermittent | Continuous or intermittent |
| Upper Limit Operating Temperature | +50°C |
| Number Of Shafts | 1 (Single-shaft design) |
| Test Medium | Air / fuel gas for functional tests |
| Turbine Cycle | Open Brayton Cycle |
| Insulation Class | Class F or H |
General Terms
- ReflowX and the seller retain the right to evaluate and approve offers.
- Buyers should verify quantities and conditions upon delivery.
- After successful engagement, both buyer and seller manage communication for payment terms and delivery schedule.
- All parties agree to adhere to ReflowX Terms and Conditions in transactions.
- Buyers can request value-added services such as pre-purchase inspections, Expediting & Delivery Services through ReflowX. Contact us!