- All Listings/
- Power Generation/
- GE MS9001E & Toshiba Multi-Shaft Combined Cycle Package 310 MW
Description
| Specification | Details |
|---|---|
| Manufacturer | GE & Toshiba |
| Model | MS9001E (PG9161E / upgraded PG9171E) & TCDF‑23" Steam Turbine |
| Year of Manufacture | 1990 & 1991 |
| Commissioning Year | 1990 & 1992 |
| Condition | Used, maintained under OEM standards |
| Quantity Available | 4 Gas Turbines (GT) & 2 Steam Turbines (ST) |
| Power Output | GT: 102 MW each / ST: 109 MW each |
| Fuel Type | Dual Fuel (Gas & Oil) |
| Frequency | 50 Hz |
| Configuration | Multi‑engine combined cycle |
| Generator / Alternator | GE 9H2 (128.6 MVA, 11.5 kV) & Toshiba TAKL (145 MVA, 13.8 kV) |
| Operating Hours | GT: 121,500 – 132,100 / ST: 147,931 |
| Total Starts | 333 – 1,020 |
| Current Status | Retired / Decommissioned |
| GT Design | 17‑stage compressor, 3‑stage turbine, 14 dual‑fuel burners with water injection |
| GT Heat Rate | 11,317 kJ/kWh (LHV) |
| ST Design | 28 wheels, 16 HP stages, 6 LP stages per flow |
| Cooling System | Hydrogen‑cooled generators |
| Maintenance | Multiple CI, HGPI, and MO inspections; final overhauls completed 2012–2013 |
Technical Details
| Year of Manufacturing | 1990 & 1991 |
|---|---|
| Model Number | MS9001E (PG9161E / upgraded PG9171E) & TCDF‑23" Steam Turbine |
| Fuel type | Dual Fuel (Gas & Oil) |
| Usage Hours | GT: 121,500 – 132,100 / ST: 147,931 |
| Manufacturer Name | GE & Toshiba |
| Year of Manufacturing | 1990 & 1991 |
| Model Number | MS9001E (PG9161E / upgraded PG9171E) & TCDF‑23" Steam Turbine |
| Fuel type | Dual Fuel (Gas & Oil) |
| Voltage | GE 9H2 (128.6 MVA, 11.5 kV) & Toshiba TAKL (145 MVA, 13.8 kV) |
| Temperature Range | 11,317 kJ/kWh (LHV) |
| Usage Hours | GT: 121,500 – 132,100 / ST: 147,931 |
| Manufacturer Name | GE & Toshiba |
| Year of Manufacturing | 1990 & 1991 |
| Model Number | MS9001E (PG9161E / upgraded PG9171E) & TCDF‑23" Steam Turbine |
| Ready for Inspection | Yes |
| Owner type | Direct Owner |
| Availability Status | Available |
| Frequency | 50 Hz |
Supporting Documents
General Terms
- ReflowX and the seller retain the right to evaluate and approve offers.
- Buyers should verify quantities and conditions upon delivery.
- After successful engagement, both buyer and seller manage communication for payment terms and delivery schedule.
- All parties agree to adhere to ReflowX Terms and Conditions in transactions.
- Buyers can request value-added services such as pre-purchase inspections, Expediting & Delivery Services through ReflowX. Contact us!