| ISO 15926 Pt 4
|
7985
|
|---|---|
| PCA RDS Code
|
RDS327239
|
| CFIHOS ID
|
CFIHOS-30000550
|
| IFC Class
|
IfcPump
|
| Explosion Protection Gas Group
|
IIB
|
| Explosion Protection Temperature Class
|
T4
|
| Explosion Protection Zone
|
Zone 2
|
| Lower Limit Operating Temperature
|
-20°C
|
| Operation Continuous Intermittent
|
Continuous
|
| Test Medium
|
ISO VG 46 hydraulic oil
|
| Test Pressure
|
~375 bar
|
| Normal Operating Inlet Pressure
|
0.5 bar
|
| Normal Operating Inlet Temperature
|
+35°C
|
| Normal Operating Outlet Pressure
|
210 bar
|
| Orientation
|
Horizontal
|
| Upper Limit Design Pressure
|
250 bar
|
| UNSPSC Code
|
40151500
|
| Upper Limit Design Temperature
|
+100°C
|
| Lower Limit Ambient Operating Temperature
|
-25°C
|
| Lower Limit Design Temperature
|
-20°C
|
| Lower Limit Operating Inlet Pressure
|
0.2 bar
|
| Lower Limit Operating Outlet Pressure
|
20 bar
|
| Lower Limit Operating Volume Flow Rate
|
20 L/min
|
| Pump Type
|
Gear-type or Axial Piston Hydraulic Pump
|
| Upper Limit Ambient Operating Temperature
|
+60°C
|
| Upper Limit Operating Inlet Pressure
|
5 bar
|
| Upper Limit Operating Outlet Pressure
|
250 bar
|
| Upper Limit Operating Volume Flow Rate
|
160 L/min
|