ISO 15926 Pt 4
|
7985
|
---|---|
PCA RDS Code
|
RDS327239
|
CFIHOS ID
|
CFIHOS-30000550
|
IFC Class
|
IfcPump
|
Explosion Protection Gas Group
|
IIB
|
Explosion Protection Temperature Class
|
T4
|
Explosion Protection Zone
|
Zone 2
|
Lower Limit Operating Temperature
|
-20°C
|
Operation Continuous Intermittent
|
Continuous
|
Test Medium
|
ISO VG 46 hydraulic oil
|
Test Pressure
|
~375 bar
|
Normal Operating Inlet Pressure
|
0.5 bar
|
Normal Operating Inlet Temperature
|
+35°C
|
Normal Operating Outlet Pressure
|
210 bar
|
Orientation
|
Horizontal
|
Upper Limit Design Pressure
|
250 bar
|
UNSPSC Code
|
40151500
|
Upper Limit Design Temperature
|
+100°C
|
Lower Limit Ambient Operating Temperature
|
-25°C
|
Lower Limit Design Temperature
|
-20°C
|
Lower Limit Operating Inlet Pressure
|
0.2 bar
|
Lower Limit Operating Outlet Pressure
|
20 bar
|
Lower Limit Operating Volume Flow Rate
|
20 L/min
|
Pump Type
|
Gear-type or Axial Piston Hydraulic Pump
|
Upper Limit Ambient Operating Temperature
|
+60°C
|
Upper Limit Operating Inlet Pressure
|
5 bar
|
Upper Limit Operating Outlet Pressure
|
250 bar
|
Upper Limit Operating Volume Flow Rate
|
160 L/min
|